Input Gain Faders -20dB to 0dB
Input Meter -30dB to 0dB with an integrated Threshold control, Peak Hold indicators
Output Meter -30dB to 0dB with an integrated
Output Ceiling control, Peak Hold indicators
Link Links Threshold and Output Ceiling
Release 0.01ms to 1,000ms
Attenuation Meter 0dB to 30dB with peak hold indicator
IDR™ Controles
- Quantize None, 24, 20, 16, 12 or 8bit
- Dither Type 1, 2 or none
- Shaping Moderate, Normal, Ultra or None
Domain Analog or Digital |